Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Other Interfaces

Showing 88 of 4893

Support for 'Short' data type for PI AMI Interface for Itron OpenWay Collection Engine

The 'Short' data type of a Register Value is not currently compatible with the interface. The user guide does not explicitly mention 'Short', and it denotes that the supported PI Point types are Float32, Digital, String. Of which, none are technic...
Robert Reed over 1 year ago in PI Interfaces / Other Interfaces 0 No status

Add new feature to allow PI Citect Interface to use the syntax [] to select an element of an array.

The ability to address parts of an array via the Citect API will cut down the number of Citect variables that need to be created so that they can be collected by the PI Citect Interface. Allow the use of syntax [] to select an element of an array ...
BrentonC almost 2 years ago in PI Interfaces / Other Interfaces 0 No status

OPC HDA Interface: Add a health digital tag for each scan class to indicate when HR is occurring versus realtime for that scan class

Add health digital tags for each scan class to indicate when HR is occurring versus realtime for that scan class. This would indicate when the interface is performing HR for the scan class and when it switches to realtime collection.
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Always use arc_append when archiving data using SIPowerTG interface

This is the interface from the Siemens Power TG EMS system. The problem is with the saving of Alarm and Event text messages. There are instances when the data files are produced out of order. When data is sent out of order the interface seems to g...
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Offset timestamps send by  PI Interface for  Environmental Systems Corp StackVision

Please allow the option to offset data sent by the interface. This will enhance the ability to compare time stamps between data sources and the PI Server  in different timezones.
Guest about 2 years ago in PI Interfaces / Other Interfaces 2 No status

Name support in BACnet Network Discovery Tool

Can you remove the restriction to use only an IP address in the BACnet Network Discovery Tool?  The interface will correctly load and poll tags to a network device referenced by name instead of IP, however the Discovery Tool has the limitatio...
Kenneth Reiss about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Emerson Ovation Interface: Enable the extraction of the full 32-bit overpacked digital tag as opposed to the now max of 16-bit

Customer would like to extract the full 32-bit overpacked digital tag into an int32 pi point.
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 Declined

Consistent Naming Convention for the UniInt Health Points Across Versions for the SNMP Interface

The health point names for the Read_Only 1.6.8.1 SNMP Interface have a different naming convention than the health points for Read-Write SNMP Interface 1.5.1.306. In order to keep monitoring consistent across version upgrades, the suggestion is to...
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 No status

SNMP Interface outputs a .txt file that includes the SNMP devices that are timed out

For the SNMP Interface, the suggestion would be to have the interface output a .txt file that includes the SNMP devices that have lost connection with the interface. This could be useful when there is a high volume of SNMP devices that connect to ...
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Quindar interface should allow tracing of values from the data source for a specified PI point.

The PI Interface for Quindar SCADA should have an option to log all values and timestamps from the data source (Prior to any processing by UniInt) for a specified PI point.
Guest about 2 years ago in PI Interfaces / Other Interfaces 1 No status