Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest about 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

change Http code 101 message from "No Content" to "Switching Protocols" on PI Web API

Hi AVEVA Team we found the issue about PI Web API. Once a client making connection to PIWebAPI over websocket (open chanel), PiWebAPI response with "HTTP code 101 No Content" instead of "HTTP code 101 Switching Protocols" Can we change response me...
Guest over 2 years ago in Developer Resources / PI Web API Samples 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Output at close option on EFGen

It would be interesting to have an 'Output at close' option on EFGen like we have on a normal Event Frame Generation.
Carlos Castro over 2 years ago in PI Interfaces / Other Interfaces 1 Declined

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Upgrade PI Interfaces for BACnet

In testing of the PI Interface BACNet, the BVRATE value does not reflect the I/O Timeout value, even in the latest version. We are not sure if this behavior was originally intended or not. Please investigate the cause of this behavior and implemen...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

EFGEN - Remove dependency for existing tags for interface to start up.

We recently ran into an issue where a few PI tags were retired, but the corresponding EFGEN interface configuration that used the tags were not retired. On the next reboot, the EFGEN interface would not start back up, since the tags could not be f...
Guest almost 3 years ago in PI Interfaces / Other Interfaces 1 Declined

Add to performance counter status of notifications rules that are with errors (deleted or renamed analysis )

Today, if any analysis that is used in a claim rule is deleted or renamed, the status of the notifications is still "successful" or "good" but an error remains because the trigger is still using an analysis that was removed or renamed. There is...
Guest about 3 years ago in PI Interfaces / Other Interfaces 0 No status