To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 104 of 5194

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automated Backups of PI Vision Displays

I've seen a few requests similar to this one but wanted to submit this with a little more specific info. I am aware of the ability to script the backup/exports of PI Vision displays using the PI Vision API and Powershell for example, but as i unde...
Justin Jackson about 2 years ago in AVEVA™ PI Vision™ / Administration 1 No status

Monitor PI Vision Health Remotely with PI Vision API

As an Administrator, I would like a new PI Vision API endpoint that exposes PI Vision health/diagnostic information so that I can monitor the PI Vision server remotely.
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 1 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Drag and drop display(s) into folders

Ability to directly on PI Vision drag displays into folders to move them. Furthermore, select multiple displays and drag & drop them into a folder.
Carlo Villarreal Escudero about 3 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Self-Heal PI Vision post-SQL outage

When the SQL Server (or listener / AG) are unavailable and restored, PI Vision does not recognize that the database is available / connectable again. This requires restarting PI Vision after a SQL outage to ensure the application is usable again. ...
Tyler Engelhardt almost 2 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Set the order of the root import folders when more than one root folder is defined

Customer Issue: Import folders are listed in the order they are added which makes it difficult to sort them if more folders need to be included later. Enhancement Request: Allow administrators to set the import folder order. Workaround: If pos...
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 0 Declined

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Detailed Display Status Report

When building displays with a large number of attributes being used it is very easy to make mistakes. Applying the wrong tag, or duplicating tags, is very easy to do but hard to troubleshoot. ProcessBook had a display status report. It is similar ...
Brian Bolton almost 3 years ago in AVEVA™ PI Vision™ / Administration 1 No status