To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 716 of 5275

Dynamic Rule for Replacing Special Character from Tag and Attribute Name while Shaping View in Designer

Currently we have our end application which cant consume Attribute names which has certain special characters such as ':', currently in PI Integrator we have an option to create alias for each attribute. But we would like have an option to create ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

amqp

Support AMQP over Websockets to allow streaming to Azure IoT Hub using only HTTPS/port 443 to be more compatible with firewalls and proxy servers.
Steve Boyko over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow option to include SYSTEM Digital State in value column

Currently, whenever there is a SYSTEM Digital State written to a PI Point attribute, the PI Integrator for BA will output a null and to be able to publish the state value, an additional data column for status needs to be added. It would be nice ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Streaming views without time delay

Messages sent to Kafka targets from streaming views are sent in batches, which causes unwanted delay for the first created messages in the batch. Our users need the streaming data without delays. Send the messages as they are created, without time...
StefanFors over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Limit IP ranges on nodes

As a PI Cloud Connect user, I would like to screen receiving Vendors via their account, but by also by limiting connections to a specific IP or IP range for connections.
Guest over 3 years ago in PI Cloud Connect 0 No status

PICC Admin Portal Log Availability

It would be useful for the PI Cloud Connect (PICC) portal to include logs related to user activity on the portal such as subscriptions, users, or publications added or removed. The current logs are local and service specific. An enhancement of PIC...
Guest over 3 years ago in PI Cloud Connect 0 No status

Identify a subscription's name from its GUID

- When PI Cloud Connect (from subscriber end) create PI tags on a destination PI server, the exDesc of those tags show the GUID of the subscription that owns it. But there's no built-in way to identity the subscription's name based on the GUID. -...
Guest over 3 years ago in PI Cloud Connect 0 No status

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Nico C about 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Warning on PI Point Prefix value when adding a target PI Server

When creating a Destination PI Server on a Connector, it automatically gets assigned a default PI Point Prefix. Therefore if you delete and recreate a Destination PI Server, the Prefix will get reverted back to the default value. Please add a war...