Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 68 of 5194

Add the “Create Timestamps” functionality back into the OPC DA Server product

In the PI OPC DA/HDA Server 2010 product, there was a “Create Timestamps” functionality (found in the OPCServerConfig Tool). This option had the PI OPC Server create timestamps for OPC clients. I rely on this functionality heavily for an OPC clien...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 0 Declined

Have the PI OPC DA Server not rely on cache files (SavedNamespace.xml) for tag changes

It would be beneficial to some customers to not have to restart the PI OPC DA Server or delete the SavedNamespace.xml in order to keep track of tag changes.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 1 No status

Use the most recently used Locale as the default

The default Locale is currently "English - United States" for all new data sources. Please consider using "English - United States" as the default Locale only for the 1st data source, and using the most recently used Locale as the default for all ...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Enable PI UFL Connector to read csv with empty data fields, eg. no value between commas

Enable UFL Connector to interpret two consecutive commas in a csv file to mean that the data field is empty. The UFL connector should interpret this empty field as a zero.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

PI UFL Connector - enable option to treat nulls values for fields as their defined data type instead of as strings

When the UFL connector sends a value that is null, it is treated as a string. As a result, any variables that are defined as other data types (other types as listed here https://docs.osisoft.com/bundle/pi-connector-for-ufl/page/field-section-state...
Paul Kim over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI OPC DA Server should update cache file or have the possibility not to work with it

Cache file is not updated till OPC server is restarted, even though new points have been added to the server and it seems it detects them We have faced issues where adding a point to the server works fine and then de point disappears when the serv...
asanzacedo about 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 0 No status

PI OPC Server 2017 - SDK Aliasing

With PI OPC DA Server 2017, SDK aliasing is no longer supported. It would be nice to be able to not reconfigure the client's ItemIDs and use an alias after migrating a Data Archive.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 0 Declined

Allow editing of the PI OPC DA Server ItemID

The ItemID of PI tags retrieved using the PI OPC DA Server has a backslash. In order to maintain consistency with browsing for OPC tags on their client, is there a way to remove or replace the backslash in the ItemID? For example, .sinusoid instea...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 1 No status

Remove conflict between TAU framework and PIBufSS

We should be able to use buffering on one tag that is fed by the connector, in case there are moments when data has to be primed into it using AFSDK.
Alan Izar over 3 years ago in PI Connectors / PI Connector for UFL 0 Declined

Be able to point the PI Connector for UFL to INI files

Please allow INI files to be pointed to by saving their full path, just like the PI Interface for UFL, rather than saving a copy of an uploaded INI file. This makes editing, testing, debugging, etc. much easier.
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 2 Declined