Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 154 of 5194

PI Manual Logger’s Conditional Manual Data Entry feature should allow conditions based on tags that are not part of the tour

Tags within the tour may require data entry based on the value of status tags for which data is never entered manually. Use Case: Say there is an asset called Pump1 that has many related tags (e.g. Pump1.FlowRate, Pump1.Pressue, Pump1.PowerConsum...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 1 Declined

Relay -> Relay communication

To accomplish a dataflow in a cross domain architecture including a DMZ, and the abbility to avoid the use of a Credential Manager it would be usefull to setup connection between two PI Connector Relays (DZM domain and PIDA domain) based on AMQPS.
Marco Blokdijk over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Increase logging for PIML Windows Service failures

When the PIML Windows Service is sending queued data to the Data Archive, it will fail if it encounters an "illegal" value.  However, the error logged only states what the illegal value was, but no identifying information about the tag or tou...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 2 Declined

PI Manual Logger Web: Floating Headers

In grid view, it would be helpful to have floating headers that scrolled down with the page as you enter data. The problem is that when you scroll down, you lose sight of what each column is and it would improve the experience if the column header...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 1 Declined

Custom Time Range for OPC UA History Read (Recovery)

It would be very useful for to be able to specify a custom time range to do a history read for on the PI Connector for OPC UA . The connector automatically does this recovery for time intervals that it internally identifies as gaps. However, many ...
Drew Hoffman over 2 years ago in PI Connectors / New PI Connector Request 0 No status

Ability for tour to have multiple tiers of approval

As an administrator, I would like for PI ML to have the ability to create a multi-tier approval workflow so that manually entered data needs to be approved by one or more levels up the hierarchy before data is stored in the data archive?
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 1 Declined

PI Manual Logger WEB 2017 Barcode input during tour run

When running a web tour in PIML Web 2017, there needs to be an ability to lock keyboard input for values that are expecting a scanned input from a Barcode, QR code and RFID tag.  We realize that the scanned code is coming from the keyboard at...
l5pk75 over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 2 Declined

Have the entered data from PI Manual Logger Web be view-able from the PI Point trend and historical data table without refreshing.

It is very important in the case of downtime to see the changes in Manual Logger Web immediately to ensure the downtime and run-time events are accurately measured. Therefore having the data not update immediately in the tag trend display in the m...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

PI integrated with Project Haystack tag standard. See www.project-haystack.org for more information.

It would be very helpful if PI integrated the PI Connector with the Project Haystack tag standard. See www.project-haystack.org for more information. Project Haystack is an open source initiative to streamline working with data from the Internet ...
Guest over 3 years ago in PI Connectors / New PI Connector Request 0 No status

'Barcode, if assigned, must be scanned or manually entered before data entry is allowed' for PI Manual Logger Web

Add support for tour option 'Barcode, if assigned, must be scanned or manually entered before data entry is allowed' In PIML Mobile 2012, it can be required that users scan or enter a barcode for any tag or tag group that has a barcode associatio...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 1 Declined