To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 156 of 5218

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Digital Trends default scaling can't be customized range

Normal on and off for 1 and 0 values but due to overlap in trending, I set the range slightly higher for each component to allow better visibility on the timeline trends. This was allowed on Processbook but PI Vision doesn't allow it.
Guest 10 months ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 No status

Support for Alarms and Conditions

We need to be able to handle Alarms and Conditions into the PI system. We are moving away from OPC classic into OPC UA.
Hobbe over 3 years ago in PI Connectors / PI Connector for OPC UA 7 Declined

Trend Digital States and Enumeration Sets

Trend Digital States - Currently on a Trend Graph that is trending digital state tags, viewing the Y Axis, you can only see the bottom value and the top value within a given timerange, whereas any state that is in between this range is not represe...
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 3 Declined

Allow color edits in Adhoc display

Allow user to change color of Adhoc display traces
holemn over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status