To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 242 of 5284

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Informative error message for the OMF Client

If the OMF Type Template is missing, for example if it is manually deleted, sending an OMF Data Message via PI Web API returns the exception "Object reference not set to an instance of an object" via PI Web API. This gives no hint about the missin...
Abishek Lakandri about 1 year ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

Add a PI PowerShell cmdlet to find all installed PI software and which installation kit installed it

As someone tasked with upgrading PI environments, it would be nice if there was a tool such as a PI PowerShell cmdlet that would retrieve all of the version information for all installed PI software on a given machine, as well as which install kit...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / General 1 Declined

Import-AFXml (PowerShell) should have ContinueOnError option

Both AFImport.exe and ImportXml (AFSDK) have options to continue on error (like is something is checked out or if there is a duplicate element name). For some reason the PowerShell version doesn't. This should be added.
taterhead247 over 3 years ago in AVEVA™ PI System Access (PSA) / General 2 No status

Include overridden attributes of derived templates in Event Frame View with PI SQL DAS (RTQP)

When you create a template-specific event view, event frames based on derived templates are also returned. However, attributes which are overridden in the derived template return empty. This means more complicated queries using UNION ALL must be u...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 6 No status

Restrict Access to Web API Endpoint by User

As a PI Web API administrator, I would like to natively restrict which users can and cannot see particular URLs and controllers on my PI Web API endpoint.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 1 Declined

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration