To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Option to replicate PI Point security attribute with PI System Connector

The current version of PI System Connector does not support replicating the PI Point security attributes: •Point Security •Data Security •Data Access •Data Group •Data Owner •Point Access A further option would be to automatically create an...
Guest about 4 years ago in PI Connectors / PI System Connector 1 Declined

Collect units of measure and description from Siemens Simatic PCS 7

Support collecting units and description from the Siemens Simatic PCS 7 system and writing them to the AF attribute and the PI Point attributes.
Guest about 4 years ago in PI Connectors / Other specific PI Connector 1 Declined

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest about 4 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest about 4 years ago in PI Connectors / Other specific PI Connector 0 Declined

X509 User Token Policy

Allow future releases of the OPC UA Connector to support user authentication via certificate or IssuedToken instead of only through user/password or anonymous connection.
Guest about 4 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Make the PI Connector for OPC UA support the use of the "Reverse Connect Client Facet"

In the reverse connect methodology - The server opens the socket and calls the client with a Reverse "Hello" message. After that, the client will use the already open channel (which initially fails with establishing the handshake) and call the nor...
Guest about 4 years ago in PI Connectors / PI Connector for OPC UA 3 No status

Analysis Preview Results - Remove Table and Graph

When using the preview analysis function an an analysis with many variables the preview graph and table struggles to keep up, and uses a long time to update. When there are many variables, these are also quite useless. It would therefore be an i...
Haavard about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Logic for SQC calculations

I would like the ability to flag an SQC event only if I am in a batch, on a grade run, or in some other process condition. Right now, I am getting an SQC outside control limit when my phase is "inactive." Let there be more configuration of this in...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis service should not close opened EF when last evaluation time is exceeds MaximumAllowedAutoBackfillingSpanInHours

As PI server administrator I would like that when the Analysis service is restarted with autobackfilling enabled, if there are any EF analysis where last evaluation time is older than *-MaximumAllowedAutoBackfillingSpanInHours, EFs that are opened...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Filter/Flag PI System Generated Error Message as Analysis Inputs to prevent False Positive Evaluations

The PI data archive (and potentially other systems) can generate many automated error messages to assist with troubleshooting. One such key example is "[-10767] Client exceeded maximum concurrent queries in RPC thread pool", which occurs when a se...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status