To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 117 of 5219

Purge EFs using AFDIAG and more search criterias'

You should be able to urge EFs using more complex search criterias' than the ones provide in the latest PI Server 2018 SP3 (StartTime, EndTIme, EF Template). Most important criteria would be EF categories, but also some honorable mentions: 1. EF ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

Limit visibility of EF to those of which the user has read access to the primary element

Currently the visibility of Event Frames in PI Vision and elsewhere is only limited by the security of those Event Frames. As the security of Event Frames created by Analyses is dependent on the security settings of the Event Frame template (and t...
Christoph Rose over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

Automatic Event Frame Name Reevaluation

I would like to see an option on an event frame generation analysis, probably under advanced event frame settings, that enables automatic event frame name reevaluation at the end time of the generated event frame. Right now I have event frame gene...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

PI Connector for Siemens SIMATIC PCS7 Alarm and Conditions backfilling support

In case of an interruption, the PI Connector has the current capability of backfilling any tag data from the source OpenPCS 7 system. Condition data leading to PI Event Frame creation from the connector should also support similar backfilling cap...
Archie Gale over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Option to set Client_ID parameters in MQTT SparkPlug Connector.

We need to have an option to set the Client ID parameter. We need an option to set the starting set of the characters of the parameter to have the possibility to use the fixed text "cva::" before a random number. Thanks
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

Multiple Event Frames generation

I want the ability to have simultainiously events generated from the same analyses. The way now is that a event frame must be closed before a new event is generated.
Hobbe over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 3 Declined

Export Event Frame Analysis Reference

The AF XML Import/Export is described by OSIsoft as a tool for backing up and restoring an AF database to either the same server or a different server. However, one object relationship that is not included in the XML file is an Event Frame's refer...