Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Option to disable TLS1.0 and 1.1 for PI AMI Interface for Itron OpenWay Collection Engine

Currently, TLS 1.0 and 1.1 cannot be disabled for the PI AMI Interface for Itron OpenWay Collection Engine. An option/method to disable TLS1.0 and TLS1.1 would be beneficial to address security concerns and vulnerabilities.
Guest 25 days ago in PI Interfaces / Other Interfaces 0 No status

Tag groups should be based on both InstrumentTag and ExDesc fields

Assume the following use case. There is a database table which stores quality limits (Lower, Target, and Upper) for product quality attributes. These could include attributes like Sample Counts, Minor Defect Counts, Major Defect Counts, Critical D...
Kenneth Reiss about 1 month ago in PI Interfaces / PI Interface for RDBMS 0 No status

PItoPI: Exception reporting is bypassed without /SN parameter

The PI to PI interface bypasses exception reporting when moving data from source to destination PI server. The alteration to the PI to PI architecture should be rectified in the next update of the PI to PI interface. There is an existing KI for th...
Timothy Grindstaff about 1 month ago in PI Interfaces / PI to PI Interface 2 No status

Reduce PI ICU Lauch Time

PI Interfaces are still very much widespread and as such PI ICU is used frequently by PI Engineers to create and configure interfaces to the PI System. PI ICU is a frequently used application but in the current layout, every time PI ICU is launche...
Moshe Sabag 4 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Support PI formula attributes for the PI to CONNECT transfer

Problem: Currently, formula attributes from PI assets are not replicated. Formula attributes are important structures for machine data as well as business logic and therefore indispensable for countless applications of CONNECT Data Services and th...
Guest 10 days ago in PI to CONNECT / General 0 No status

Replication of tag attributes

Provide the possibility to manually select replication of tag attributes as stream metadata. Besides None, Low, Medium, High in the Stream Metadata Replication Policy of a transfer there should be a "Custom" option to select additional tag attribu...
Hans-Otto Weinhold about 2 months ago in PI to CONNECT / General 0 No status

NLog for PI Batch Interfaces

PI Batch Interfaces 5.0 or later log messages to Windows Event Viewer, which can lead to them being quickly overwritten and making troubleshooting issues or performing root cause analyses more difficult. It would be great if they used NLog as othe...
Rafael Batista 4 months ago in PI Interfaces / Batch Interfaces 0 No status

PI Batch Interfaces (EFGEN) Reliability During Recovery Runs

The Batch interfaces currently handle recovery processes very unreliably which could end up stopping the whole AF server. We believe the stability of the interface running recoveries should be carefully handled to ensure the whole AF server enviro...
Moshe Sabag 4 months ago in PI Interfaces / Batch Interfaces 0 No status

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 3 months ago in PI to CONNECT / General 0 No status

Improvement: EFGen in PIBaGen compatibility mode it is not possible to disable merging at the Procedure/Batch level

It would be nice if it was possible to configure PIEFGen in PIBaGen mode to configure it to either merge consecutive event frames or disable merging of consecutive event frames at the Procedure level. For example, in PI Batch Generator interface c...
Guest 17 days ago in PI Interfaces / Other Interfaces 0 No status