To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Evaluating

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / General 2 No status

Let subscribers set timezone for alerts

As a notification subscriber I want alerts to be sent using timestamps in my timezone so that I don't have to do mental conversion to interperate an alert.
Guest about 4 years ago in AVEVA™ PI Server / Notifications 3 Declined

On the "Configuration" home page, be able to double-click on an AVEVA Adapter instance to configure it

Currently, to configure an AVEVA Adapter instance, you need to go to the "Configuration" home page, click on the AVEVA Adapter instance, and then click on the "Configure Adapter" button. It would be much faster if we could also just double-click o...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Combine all logging parameters into a single table

Logging can be configured for each component as well as at the adapter level. Any AVEVA Adapter instance will have at least 3 areas where logging can be configured: the adapter, the OmfEgress component (always present), and the adapter components ...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Allow Payload edits for Sparkplug B

I have devices that are outputting utilizing Sparkplug B and the current adapter is not picking up what your techs are calling the high register, so my tags are recording values of 0 instead of actual time. Here is resolution to one of my tickets ...
aclaus 2 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Make the right pane resizable

The right pane appears whenever you try to edit an item in a collection of items (e.g. when you try to edit a schedule, of which there can be multiple). It is currently not resizable, even though the left pane is. Please make the right pane resiza...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Fix the description for "Connect String" for the AVEVA Adapter For RDBMS

When you configure a data source for the AVEVA Adapter For RDBMS through the AVEVA Adapter Configuration Utility, the description for "Connect String" is just "DSN". A connection string is more than just a DSN and does not even need to reference a...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

By default, the "Validate Endpoint Certificate" check box should be checked

According to the documentation of any AVEVA Adapter, the default value of the "validateEndpointCertificate" parameter is "true", which is good from a security standpoint. However, in the AVEVA Adapter Configuration Utility, the "Validate Endpoint ...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Do not store the entire connection string ("connectString" parameter) as a secret

Currently, the entire value of the "connectString" parameter is stored as a secret to be able to protect any passwords that might be used in the connection string. Since the connection string is stored as a secret, it cannot be read by users after...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status