To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes

Showing 5209 of 5209

Trend: Logarithmic Scale

in some of our processes, we have pressure close to vacuum. in this case we need a logarithmic scale. until now, it's not possible to configure PI Vision trends with a logarithmic scale.
FranzK over 3 years ago in AVEVA™ PI Vision™ / Symbols 6 Declined

Add "Sequence of Events" Symbol Type

Add a table symbol which consists of the following 3 columns: Tag Name Tag Value Tag Timestamp (default sort on this column, ascending order) This table would consist of a set of tags over a specified time range. The purpose of this "Sequence ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

Support security baselining

As a PI administrator, I need to baseline the security configuration of my PI System to ensure OSIsoft security best practices are followed. Below is a list of requested features. Baseline verification (read-only) for PI Data Archive: - PI Data ...
Guest over 3 years ago in Developer Resources / PI System Deployment Tests 2 No status

Show transparent shapes in design mode

When modifying a display you cannot see where transparent shapes are. If they could be made visible when in design mode it would be far easier to maintain displays.
Mike Horrocks 7 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

Export data from the Display Sessions to a PI Point through an interface or performance counter

The Display sessions are very useful for daily monitoring. But having the option that allows us to save the data from this utility to a PI Point or attribute for later analysis would be useful for monitoring purposes
Guest 7 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Improve performance

Please find a way to improve performance when needing to view 100+ days of data in dashboards. Potentially defaulting to 5mMID ( or less resolution) would help this
Guest 7 months ago in AVEVA™ PI Vision™ / User Experience 1 No status

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Dark Mode (theme) for PSE and SMT

No description provided
Gabriel Verreault over 3 years ago in AVEVA™ PI Server / General 7 No status