Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4917

Create a PI connector/interface for devices communicating using the BACnet/SC protocol

The instance of the PI system that the group I work in is over 50% complete in integrating the JCI Metasys building control systems from 190 facilities. The software/firmware of the devices that comprise the JCI Metasys system we are using current...
Daniel Chiariello 3 months ago in PI Connectors / PI System Connector 0 No status

Assign units to tag-based calculation

When creating a tag-based calculation, allow the user to set unit of measure through a text field. The units can then be displayed within symbols on the main display.
Amit Dutta about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Conditional Data Egress for Edge Data Store

Scenario: In a remote monitoring scenario, Edge Data Store is collecting data through OPC UA or ModbusTCP with a certain sampling rate (assumingly 1s). For normal operations, EDS shall egress only an aggregated one minute value of all analogue str...
Guest 10 months ago in Edge Data Store / Egress 0 No status

RTQP 2023 SP1 SQL database execution script to be made available for download from customer portal

We might still need the SQL script because when the installer failed to run successfully for some reason, the SQL scripts won't be present. AF SQL database execution script used to be available to download from customer portal until version 2018 S...
Ee Sheing Lee 10 months ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks 10 months ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

Allow selective AF Database indexing

The PItoDatahub agent will index the whole AF server. On big ones, this is tedious (one took more than 12 hours) - would prefer to have the ability to choose either on the agent or from ADH which AF databases to index.
Guest over 1 year ago in PI to CONNECT / General 1 No status

Display Attributes with PI Tag Names in Pi Vision Display

It would be helpful if PI Vision would have a symbol or allow users to create a custom symbol where we can show a table of attributes and their associated PI Tag names. This would be useful for operators and engineers working in the manufacturing ...
Guest almost 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Allow PI Web API Admin Utility to run silently

We use the command following command to run the PI Web API Admin Utility silently in order to automate SSL certificate updates: OSIsoft.REST.Admin.exe --f=C:\temp\InstallationConfig.json --suppressUI=0 --verbose If the admin utility crashes, this ...
Guest 7 months ago in Developer Resources / General 1 No status