To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4928

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 2 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

PI DataLink on MS 365

It will be great to have PI DataLink Add-on works on Microsoft 365 or allowing PI DataLink reports to be hosted in PI Vision.
Husain Al-Shaikh 3 months ago in AVEVA™ PI DataLink™ / Programming 0 No status

Monitor Resource Intensive Displays

When IIS workers have high CPU usage, there is no visibility to the user + display causing the issue. Provide some type of diagnostics to expose this.
Brian Deslatte 6 months ago in AVEVA™ PI Vision™ / User Experience 0 No status

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 2 years ago in AVEVA™ Adapters / General 2 Future consideration

Support AWS RDS as PI Vision backend

Our company is progressively superseding the deployment of hosts with SQL Server installed, while moving towards the usage of SQL Server instances provided by AWS' Relational Database Service as the DB backend. Although currently AVEVA does not of...
Kevin Geneva 6 months ago in AVEVA™ PI Vision™ / Administration 1 No status

Check history of data discovery in the OPC UA Connector for a data source

Need the option to check historical data discovery dates and times from an OPC UA Connector's data source. There is a Last Discovery performed in the DATA SOURCE TOOLS, however, we should be able to see all of the "Last Discovery" of the data source.
Adam Paranick about 1 month ago in PI Connectors / PI Connector for OPC UA 0 No status

PI Data via MQTT Broker

Allow external applications to consume PI system data via MQTT.
Guest over 2 years ago in AVEVA™ PI System Access (PSA) / General 2 No status

Expose methods to retrieve messages from the PI Message log to PI AF SDK

Add methods to retrieve messages from the local and remote PI Message Logs where remote can refer a PI Data Archive node or any remote PINS. Because the EventLog Class in .NET Framework provides access to local and remote Event Logs, offering th...
Guest over 2 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 3 Declined

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 over 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status