To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 518

Remove or disable the PI Connector UFL function which puts "Excluded" into attributes

If the user has two different UFL flows working on same elements and attributes, one flow puts "Excluded" into the attributes created within the second one and vice versa. Giving the possibility to the user to disable this function would be a sma...
rodolforotti over 3 years ago in PI Connectors / PI Connector for UFL 1 Declined

Continue to support/modify the PI Trend Add-In for Excel DataLink that was in 2014 on into 2016 and beyond.

This add-in allowed for a trend to be created within an Excel Spreadsheet without first dumping the data to the sheet.  It was an easy trend to make and it updated with current live data when requested (F9). There is a work around to get thi...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 8 Declined

Ability to monitor which OPC UA Connector is active in a failover pair

As a PI administrator, I need to monitor which OPC UA Connector in a failover pair is currently active. When the primary OPC UA Connector goes down, I need an email notification, and vice versa when the secondary OPC UA Connector goes down.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Connector (UFL) can read AF data structure

Right now it is a limitation because of the current functionality / design. In the future it would be nice if: - the connector can read the existing AF structure - update the existing AF structure - create elements / EF / attributes under existin...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 Declined

PI Connector for MQTT sparkplugB - support Changes to the STATE message in the Sparkplug v3.0.0 Specification

PI Connector for MQTT SparkplugB: Using the connector as the Primary Host, Connector set its STATE topic to ONLINE or OFFLINE only. Connector should support the new format of STATE (and it's payload) topic in the v3: As per Changes to the STATE me...
Ee Sheing Lee 7 months ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for Modbus TCP

Develop a PI Connector for Modbus TCP.  Connectivity to Modbus slave devices; used for general purpose connectivity to many legacy industrial devices. Interoperable with Edge Data Store (EDS) and OSIsoft Cloud Services (OCS).
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Ability to search for Data Items on multiple PI Server and/or AF Servers

Allow multiple PI or AF servers to be selected when searching for Data Items. Currently, search allows only searching on a single server or all servers. Note: This was previously Enhancement 26673OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Search 0 Declined

Enable designation of logical relationship for multiple Attribute filters

Allow the designation of the logical relationship between multiple Attribute filters. Current filters are locked exclusively in an 'AND' relationship. It would be helpful to be able to set the relationship to 'OR'. For example, in searching throug...
RandyHawley about 2 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...