To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 553 of 5273

Ability to edit some PI-AF properties from PI Coresight, i.e.: Light-weight PSE

PSE is often used as a client-tool where it is not intended to be. It would be very beneficial to have a simple PSE tool just to view data. Browse Element Hierarchies and view Attributes, EventFrames. Just like PSE. The hierarchy could also make a...
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 3 Declined

Support of more than 1 reason code

As a user, I would like to enter more than 1 reason code per event frame. For example, a downtime event frame is created for the whole production line, and I would like to have a reason code for the cause and the other for the equipment. Currentl...
Willy Seah Wei Liat over 3 years ago in AVEVA™ PI Vision™ / AF Integration 5 Declined

Support multiple PI to CONNECT Transfers with one agent, from a single Data Archive

As a System Administrator in charge of deploying software at my organization, I would like PI to CONNECT to support multiple transfers from a single Data Archive, with a single agent so my Data Owners can manage the transfer of data without impact...
Guest over 3 years ago in PI to CONNECT 1 No status

Connector (UFL) can read AF data structure

Right now it is a limitation because of the current functionality / design. In the future it would be nice if: - the connector can read the existing AF structure - update the existing AF structure - create elements / EF / attributes under existin...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 Declined

PI Connector for Modbus TCP

Develop a PI Connector for Modbus TCP.  Connectivity to Modbus slave devices; used for general purpose connectivity to many legacy industrial devices. Interoperable with Edge Data Store (EDS) and OSIsoft Cloud Services (OCS).
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

OPC UA - Add Option to not browse item before creating a monitored item

Need an option in Tag only Mode to force connector to create a monitored item without browsing item. Some OPC servers require creating a monitored item BEFORE the item can be browsed.
JTWhite over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Support derived templates

When replicating AF data to CONNECT, I would like to make sure that all assets configured from templates which are themselves based on derived templates, preserve the template inheritance. For instance, if I have a Mobile Equipment template, with ...
Max McKay over 1 year ago in PI to CONNECT / General 0 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

Configure PI to CONNECT Transfer Configuration via CSV or other file import

In addition to building the transfer list via searching a data archive, it would also be good to allow the user to reference a file (e.g. CSV) that has a list of points to transfer.
Guest over 3 years ago in PI to CONNECT 3 No status