Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 116 of 5219

Apply the Connector Relay to IEC 60870-5-104 Connector

Adding the Relay and the DCM framework to the "legacy"IEC 104 Connector in order to improve the architecture management and security
marcogiunti over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

PI Connector for IEC 60870-5-104 bi-directional between SCADA and PI

RWE Power AG “But one really important feature we need, is the ability to write back from PI into the SCADA system Until now, we couldn’t find anything about this (important) functionality. So our question is if we can use this connector bi-dire...
Guest over 3 years ago in PI Connectors / General 4 Declined

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest over 3 years ago in PI Connectors / General 0 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer over 3 years ago in PI Connectors / General 5 No status

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 3 years ago in PI Connectors / General 1 No status

Merge Two Tags or Copy Tag Data to a New Point

Sometimes, when dealing with APS, a new TAG is generated for an existing point. Data stops going to the old point. It would be nice if there was an easy way, within the gui (not manually dumping and importing) that we could take the values from on...
Guest over 3 years ago in PI Connectors / General 4 Declined

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for MQTT sparkplugB - support Changes to the STATE message in the Sparkplug v3.0.0 Specification

PI Connector for MQTT SparkplugB: Using the connector as the Primary Host, Connector set its STATE topic to ONLINE or OFFLINE only. Connector should support the new format of STATE (and it's payload) topic in the v3: As per Changes to the STATE me...
Ee Sheing Lee 8 months ago in PI Connectors / Other specific PI Connector 0 No status

Reduce Number of Point Sources for PI Connector for PI System Health

PI Connector for PI System Health creates a LOT of different point sources for the Pi points it creates on the Data Archive. Some customer may prefer to not have so many point sources show up for one interface/connector. Adding a method to reduce/...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status