To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 372 of 5219

Allow Asset Analytics to output to annotations

As someone who has migrated our calculations from PI ACE to Asset Analytics, we need to be able to annotate various calculation outputs in the same way we were able to with PI ACE. Please enable analyses to output annotations to various PI Tags in...
Roger Ward over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Ivan Lozanov over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

Remove requirement for shared volume for PI Analytics and PI Notifications high availibility

Our corporation has highly available PI in a number of sites. Our PI infrastructure is highly available except for Analytics and Notifications. The requirement for a shared volume for the failover cluster is not supported. We can support the failo...
Nathan Anderson 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Clint Ramsey over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
taterhead247 over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Recover data from current time moving backwards

Recover data from the current time back rather than start of a data gap to now (current time). The most important thing is to get current data immediately.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined