To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Notifications for events in the past

Currently notifications are not triggered (send) by events that are more than 72 hours in the past. For me it is necessary to get notifications from events in the (endless) past. Ideally I would like to configure for each notification separately t...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 8 No status

Change time range defaults

The current time range defaults are 1h 8h 1d 1w 1mo. Please can you make a way admins can change the defaults for their company (for example replace the 8h button with a 1y), or admins can create new defaults? A 3d and 1y button would be very help...
Kelly Campbell over 1 year ago in AVEVA™ PI Vision™ / Display Management / Displays Page 4 Already exists

Allow AIM to directly authenticate users from other Identity Providers without CONNECT

Currently, AIM can only use CONNECT or Microsoft Entra ID as the main Identity Provider. Configuring any other IDP requires federation through CONNECT. Allowing other IDPs to work directly with AIM without CONNECT would simplify the OIDC configura...
Dan McGovern 10 months ago in AVEVA™ PI Server / Security 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Nick Ciampa 6 months ago in AVEVA™ Adapters / New Connectivity 1 No status

Ability to send a notification without being triggered by an event frame

As a notification user I want to receive a report on daily or weekly basis but I don’t want to store any associated data about it like the event frame information or the notification history since I use event frames for other purposes and I don’t ...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 3 No status

Composite element templates

As an user I want to be able to create a template hierarchy (parent-child) all at once, so that I can easily create a hierarchy representing related assets. For example, create a motor, gearbox, compressor train with a single template that actuall...
Guest about 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 4 No status

Support Reverse Connect

Reverse connect allows a Server to initiate the connection to a Client (open the socket sending a HEL message). This results in an additional security concern for the Client, in that the Client needs to validate that the connection is from an appr...
Alan Izar about 1 month ago in AVEVA™ PI System Access (PSA) / AVEVA PI OPC UA Server 0 No status

Support Certificate Management via GDS

AVEVA PI OPC UA Server should support registration at a Global Discovery Server for easier Certificate Management and role implementation.
Alan Izar about 1 month ago in AVEVA™ PI System Access (PSA) / AVEVA PI OPC UA Server 0 No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status