Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 307 of 4905

EFGEN - Remove dependency for existing tags for interface to start up.

We recently ran into an issue where a few PI tags were retired, but the corresponding EFGEN interface configuration that used the tags were not retired. On the next reboot, the EFGEN interface would not start back up, since the tags could not be f...
Guest over 1 year ago in PI Interfaces / Other Interfaces 1 Declined

Enable logging of 5.x batch interface messages to the local PI message log again

Message logs for 5.X Batch interfaces and Connectors are written to Windows Event Viewer instead of PI Message Logs as in previous versions. The Windows Event Log is extremely slow compared to viewing PI message logs, the filtering is worse, the m...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 2 Declined

Stay with RAD View

RAD view is easier to use for troubleshooting.
Guest over 1 year ago in PI Interfaces / General 0 No status

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 1 year ago in PI Interfaces / PI to PI Interface 0 No status

Add to performance counter status of notifications rules that are with errors (deleted or renamed analysis )

Today, if any analysis that is used in a claim rule is deleted or renamed, the status of the notifications is still "successful" or "good" but an error remains because the trigger is still using an analysis that was removed or renamed. There is...
Guest over 1 year ago in PI Interfaces / Other Interfaces 0 No status

Make the ICU maximize button work.

Clicking the maximize button in the ICU makes it take up the whole screen but the fields remain the same size. If the fields resized as well, it would make reading and entry in some of the smaller fields easier.
rphilp1 over 1 year ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 Declined

Support for 'Short' data type for PI AMI Interface for Itron OpenWay Collection Engine

The 'Short' data type of a Register Value is not currently compatible with the interface. The user guide does not explicitly mention 'Short', and it denotes that the supported PI Point types are Float32, Digital, String. Of which, none are technic...
Robert Reed over 1 year ago in PI Interfaces / Other Interfaces 0 No status

Revive PI EMDVBCS support to <Description> tag

Customer has been using the description tag for the Operation (OP) for the instances that get sent to OSI PI using EMR.WF.PI.Task.This atribute gets populated while they are using PI EMDVBCS v4.1.9.3669. However when they upgraded to v4.3.1.24 - t...
Gaille Pereña over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC over 1 year ago in PI Interfaces / PI to PI Interface 1 Future consideration