To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Add rotation formatting to Value

Allow rotating the Value symbol in the same way as the Text symbol can be rotated.
Jørgen Foss about 4 years ago in AVEVA™ PI Vision™ / Symbols 4 Declined

Trend: Time Range: Duration and Offset - Add option to support start time

Currently the Trend object's Time Range has a Duration and Offset option which will take the End Time of the display and a specified duration for the trend's timerange. We need to have the ability to do the same based on the Start Time and a durat...
Guest about 4 years ago in AVEVA™ PI Vision™ / Symbols 2 No status

Make the UFL Connector logic development/testing/debugging process less tedious

Deploying a UFL Connector solution requires a LOT of edits of the INI file as part of the development/testing/debugging process. After each INI file change and file save, the required procedure is as follows: 1. Click on the Data Source List link...
Mic Paluszak about 4 years ago in PI Connectors / PI Connector for UFL 0 Declined

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
Philipp Even about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
Philipp Even about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Provide easier workflow to retrieve the recorded values for EF attribute

As a DataLink user, I would like to see all the values of the event frame attributes during the start and end time using the Explore Events function so that I don't need to ask for the compressed values during that time range for each of the attri...
Guest about 4 years ago in AVEVA™ PI DataLink™ / Events (EF) 2 No status

Enable Including Event Frames in Time Based Report

It would be useful to have the possibility to include EFs in a Time Based Template. For example: - if downtime events are recorded as Event Frames, I would like to report on all the downtime EFs occurred in the last month (for example), includin...
Guest about 4 years ago in AVEVA™ RtReports 2 No status

Attributes` new name are not reflected in the Asset Comparison Table or the Collection symbol.

After updating an AF attribute name, the updated name is not reflected in the Asset Comparison Table or the Collection symbol. When an AF attribute name is changed, the Asset Comparison Table that references this attribute does not update the attr...
Hui Liu 7 months ago in AVEVA™ PI Vision™ / AF Integration 0 No status

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux over 3 years ago in PI to CONNECT / General 0 No status

Have the option to discover new data streams, auto-select them, and save data retrieved for them, all with a single query to the data source, similar to PI Connectors

Background + problem When PI Connector tries to save data for a tag that does not already exist (e.g. data for a new piece of equipment), it will create that tag automatically. This is very convenient, but it sometimes led to issues where data tha...
Kenneth Barber 2 months ago in AVEVA™ Adapters / General 0 No status