To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

For PI Points created by AVEVA Adapters, use the point class "base" instead of "classic" if the PI Point does not use "classic"-specific PI Point attributes

When an AVEVA Adapter creates a new PI Point, it always uses the point class "classic", even if none of the attributes that are specific to this point class are ever used. Instead, AVEVA Adapters should create PI Points using the point class "base...
Kenneth Barber 3 days ago in AVEVA™ Adapters / General 0 No status

Option to disable TLS1.0 and 1.1 for PI AMI Interface for Itron OpenWay Collection Engine

Currently, TLS 1.0 and 1.1 cannot be disabled for the PI AMI Interface for Itron OpenWay Collection Engine. An option/method to disable TLS1.0 and TLS1.1 would be beneficial to address security concerns and vulnerabilities.
Guest 25 days ago in PI Interfaces / Other Interfaces 0 No status

Tag groups should be based on both InstrumentTag and ExDesc fields

Assume the following use case. There is a database table which stores quality limits (Lower, Target, and Upper) for product quality attributes. These could include attributes like Sample Counts, Minor Defect Counts, Major Defect Counts, Critical D...
Kenneth Reiss about 1 month ago in PI Interfaces / PI Interface for RDBMS 0 No status

PItoPI: Exception reporting is bypassed without /SN parameter

The PI to PI interface bypasses exception reporting when moving data from source to destination PI server. The alteration to the PI to PI architecture should be rectified in the next update of the PI to PI interface. There is an existing KI for th...
Timothy Grindstaff about 1 month ago in PI Interfaces / PI to PI Interface 2 No status

Reduce PI ICU Lauch Time

PI Interfaces are still very much widespread and as such PI ICU is used frequently by PI Engineers to create and configure interfaces to the PI System. PI ICU is a frequently used application but in the current layout, every time PI ICU is launche...
Moshe Sabag 4 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Be able to save, name, and easily reuse query strings for data discoveries

Currently, the query string of a data discovery is part of the data discovery, and once a data discovery is run, it cannot be rerun since part what identifies a discovery is the time at which it ran. This is not a flaw, but rather a part of the de...
Kenneth Barber 11 days ago in AVEVA™ Adapters / General 0 No status

Allow multiple instances of an AVEVA Adapter to exist on the same server without using Docker

Currently, there can be only 1 instance of a specific AVEVA Adapter on each server if Docker is not used. However, within that instance, multiple components and data sources can be configured. This is convenient, but then the service account for t...
Kenneth Barber about 1 month ago in AVEVA™ Adapters / General 0 No status

NLog for PI Batch Interfaces

PI Batch Interfaces 5.0 or later log messages to Windows Event Viewer, which can lead to them being quickly overwritten and making troubleshooting issues or performing root cause analyses more difficult. It would be great if they used NLog as othe...
Rafael Batista 4 months ago in PI Interfaces / Batch Interfaces 0 No status

PI Batch Interfaces (EFGEN) Reliability During Recovery Runs

The Batch interfaces currently handle recovery processes very unreliably which could end up stopping the whole AF server. We believe the stability of the interface running recoveries should be carefully handled to ensure the whole AF server enviro...
Moshe Sabag 4 months ago in PI Interfaces / Batch Interfaces 0 No status

Rename services to reflect the renaming of the product

AVEVA Adapters were previously called "PI Adapters", but the name of any AVEVA Adapter service begins with "PIAdapter". The PI To CONNECT Agent was previously called the "PI To Data Hub Agent", but the service name is still "PIToDataHubAgent". I'm...