Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 74 of 5194

Allow Admins to choose what tags are needed from WiHart Connector

Currently the PI Connector for WiHart Gateway does not allow for choosing what data to collect - it just gets everything that is returned from the "canned" commands it executes against the gateways. It would be very beneficial to allow the PI Admi...
ChrisGard 14 days ago in PI Connectors / Other specific PI Connector 0 No status

Allow to attach files when opening a new case

As a customer I would like to be able to attach images, logs and all relevant information on the moment that I create a case. Today when a customer creates a new case he is able only to write text on the Case Form. And only after that he is able t...
Wagner Lima over 3 years ago in Customer Portal & PI Square / On-line Case Creation 3 Declined

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Apply the Connector Relay to IEC 60870-5-104 Connector

Adding the Relay and the DCM framework to the "legacy"IEC 104 Connector in order to improve the architecture management and security
marcogiunti over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Fix Customer Portal Timeout Issue - New Case Creation

When creating a new case, the page times out after about 10 minutes which causes all of the entry to be lost. This is especially frustrating when a significant amount of detail has been added for a more complicated case. Need the timeout duration ...
Mohammed Qasim Asghar 7 months ago in Customer Portal & PI Square / On-line Case Creation 0 No status

PI Connector for MQTT sparkplugB - support Changes to the STATE message in the Sparkplug v3.0.0 Specification

PI Connector for MQTT SparkplugB: Using the connector as the Primary Host, Connector set its STATE topic to ONLINE or OFFLINE only. Connector should support the new format of STATE (and it's payload) topic in the v3: As per Changes to the STATE me...
Ee Sheing Lee 7 months ago in PI Connectors / Other specific PI Connector 0 No status

Add a view only user type restricting option to raise support cases

We have few section of users interested in learning module and others who would be only having view (read-only) access to customer portal. The current list of user types in https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=kA0...
Guest over 3 years ago in Customer Portal & PI Square / On-line Case Creation 2 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status